GD K7D2 |
|
- Built-in sampling pump
- Complete sensor and pump in one housing
- Quick installation wall brackets
- Easy sensor and pump removal for maintenance
- Front removal cover
- Built-in flow indicator and low flow alarm
- Quick response sensors
- Over 30 sensors to choose from
- Built-in battery for bias of sensors
- Optional NEMA 4X housing available
|
The GD-K7D2 is RKI’s workhorse sample draw assembly for use with a wide variety of electrochemical sensors for toxic gas detection. It is designed for simple servicing in that the sensor and pump can be easily replaced in less than one minute each. The GD-K7D2 is normally supplied with a 115 VAC pump, which requires local AC power, and the sensor signal output is 4-20 mA (24 VDC, 2 wire loop). A 24 VDC pump is also available, in which the head uses a 3 wire connection to a controller or PLC. The compact design of the unit requires minimum mounting space and the front removal cover allows for installation and ease of service in tight spaces. Easy to install, operate, and maintain, the GD-K7D2 is RKI’s most popular sample draw head for toxic gases. |
GD-K7D2 |
Part Number |
Detector/TransmitterSample draw, Ammonia (NH3) 0-75ppm |
GD-K7D2S-NH3 |
Detector/TransmitterSample draw, Arsine (AsH3), 0-0.2 ppm |
GD-K7D2S-ASH3 |
Detector/TransmitterSample draw, Boron Trichloride (BC13) 0-5 ppm |
GD-K7D2-BCL3 |
Detector/TransmitterSample draw, Carbon Monoxide (CO), 0-150 ppm |
GD-K7D2-CO |
Detector/TransmitterSample draw, Chlorine (C12) 0-3 ppm |
GD-K7D2-CL2 |
Detector/TransmitterSample draw, Diborane (B2H6) 0-0.3 ppm |
GD-K7D2-B2H6 |
Detector/TransmitterSample draw, Dichlorosilane (DCS) 0-3 ppm |
GD-K7D2-DCS |
Detector/TransmitterSample draw, Fluorine (F2) 0-3 ppm |
GD-K7D2-F2 |
Detector/TransmitterSample draw, Hydrogen Bromine (HBr) 0-9 ppm |
GD-K7D2-HBr |
Detector/TransmitterSample draw, Hydrogen Chloride (HCI), 0-15 ppm |
GD-K7D2-HCL |
Detector/TransmitterSample draw, Hydrogen Cyanide (HCN) 0-30 ppm |
GD-K7D2-HCN |
Detector/TransmitterSample draw, hydrogen Fluoride (HF) 0-9 ppm |
GD-K7D2-HF |
Detector/TransmitterSample draw, hydrogen Peroxide (H2O2) 0-3 ppm |
GD-K7D2-H202 |
Detector/TransmitterSample draw, nitric Oxide (NO) 0-100 ppm |
GD-K7D2-NO |
Detector/TransmitterSample draw, nitrogen Dioxide (NO2) 0-15 ppm |
GD-K7D2-NO2 |
Detector/TransmitterSample draw, Ozone (O3) 0-1 ppm |
GD-K7D2-O3 |
Detector/TransmitterSample draw, Phosphine (PH3) 0-1 ppm, with ES-23AH sensor |
GD-K7D2-PH3-AH |
Detector/TransmitterSample draw, Phosphine (PH3) 0-1 ppm with ES-23DH sensor |
GD-K7D2-PH3-DH |
Detector/TransmitterSample draw, Silane (SiH4) 0-15 ppm with Es-23AH sensor |
GD-K7D2-SIH4-AH |
Detector/TransmitterSample draw, Silane (SiH4) 0-15 ppm with Es-23DH sensor |
GD-K7D2-SIH4-DH |
Detector/TransmitterSample draw, SULFAR dioxide (SO2) 0-10 ppm |
GD-K7D2-SO2 |
Detector/TransmitterSample draw, Tungsten Hexafluoride (WF6) (HF) 0-9 ppm |
GD-K7D2-WF6 |
|
*Different configurations also available |